P2000

P2000 In-Situ CEM

In stack Continuous Emissions Monitoring

Protea 2000 In-Situ Infra-red gas analyser connected to a Protea Control Unit forms the basis of a Continuous Emission Monitoring System (CEMS). The Stack Mounted In-Situ analyser monitors the stack gas without the need for any sample handling equipment making it a cost effective solution to Continuous Emission Monitoring and Process applications. The analyser monitors the stack gases “wet”, water vapour is continuously monitored enabling the pollutant gases can be reported on a wet or dry bases.

The Protea 2000 can monitor up to six gas species, including NO, NO2, N2O, SO2, NH3, HCl, CH4, CO, CO2 and H2O in many CEMs and process applications. The analyser probe is heated, ensuring components in contact with the stack gas are above the dew point, enabling the analyser to be installed on highly corrosive and demanding applications such as Nitric Acid and Sulphuric Acid plants. The In-Situ analyser has been installed in over 4000 installations worldwide. The analyser is compliant with international standards such as EN14181 and US EPA 40 cfr Part 60 & 75.

The Protea 2000 requires minimal maintenance or operator intervention, capable of fully automated zero and verification the analyser, utilising advanced diagnostics will continuously report health status. The extremely low maintenance requirements make the Protea 2000 an ideal instrument for remote sites and marine applications.

Download P2000 Brochure

The Stack Mounted Protea 2000 can accept signals from adjacent instruments for example Oxygen, Particulates (Dust), velocity not only reducing installation costs but also enabling the system to report monitored concentration normalised to Oxygen or in mass units (kg/hr).

Monitoring Ranges for P2000
Principle of operation Single Beam Dual Wavelength Infra Red with GFC where advantageous.
Gases measured CO    0 - 150ppm / 429mg/m3
SO2    0 - 100ppm / 280mg/Nm3
NO    0 - 240ppm / 322mg/Nm3
CO2    0 - 15%
H2O    0 - 12%
P2000 Specifications
Spectral range Specific application dependent wavelengths (up to 8) are selected between 2-12 μm.
Infra-red source Enclosed nichrome filament.
Infra-red detector Solid state pyroelectric element.
Sample path length 1 metre
Sample Temperature Up to 350°C (660°F) (higher temperatures on application).
Cross-sensitivity Minimal due to the wavelength selection and advanced algorithms in the processor software.
Accuracy Typically ±2% of full scale concentration but dependent on application.
Response time Application dependent but typically 120 seconds to T90.
Enclosure Aluminium alloy casting with high protection finish, protected to IP65 (NEMA 4X).
Operating environment Operating temperature range -20°C to 55°C (-4°F to 130°F).
Optional Analyser Cooler/Heater for greater temperature range.
Materials-contact with gas Calcium Fluoride, Glass, 316 Stainless Steel, Graphite
Services required Power for analyser with PSU 115V/230V 175W.
Power for in situ heater (optional) 115V/230V 1kW.
Instrument air for the analyser void purge, auto zero and sample cell protection, controlled by the analyser, 2 barG; flow rate 0.5 litre/min constant and 6 litre/min intermittent during Auto-zero (typically 8 minutes every 12 hours).
Interconnection cable 2 twisted-pair cores with individual screen typically allows up to 1000m separation between Analyser and Protea 1000 Analyser Control Unit.
Weight 25 kg (46.3lb)
Physical dimensions Analyser 1360mm (53.5”) x 380mm (15”) x 315mm (12.4”)